Pulmonary Function Testing: An Interoperability on FHIR Implementation Guide
0.1.0 - ci-build

Pulmonary Function Testing: An Interoperability on FHIR Implementation Guide - Local Development build (v0.1.0). See the Directory of published versions

Example Bundle: PFT Bundle

Bundle pft-bundle of type collection


Entry 1

Resource Composition:

Generated Narrative

status: PRELIMINARY

type: Pulmonary function test panel

category: Pulmonary studies (set)

encounter: Generated Summary: type: collection

date: 2017-02-20

author: TODO_PLACEHOLDER

title: PFT: test panel Observations and DiagnosticReport

custodian: Generated Summary: type: collection


Entry 2

Resource Patient:

This resource is a stub for use in examples.

Entry 3

Resource Practitioner:

This resource is a stub for use in examples.

Entry 4

Resource Practitioner:

This resource is a stub for use in examples.

Entry 5

Resource Organization:

This resource is a stub for use in examples.

Entry 6

Resource Encounter:

This resource is a stub for use in examples.

Entry 7

Resource ServiceRequest:

This resource is a stub for use in examples.

Entry 8

Resource DiagnosticReport:

Pulmonary function test panel (Pulmonary Function)

SubjectNot done yet
When For2017-02-24

Report Details

CodeValueReference RangeWhen For
Forced vital capacity [Volume] Respiratory system by Spirometry --pre bronchodilation3.9 LFVC normal bounds: >3.7 LFeb. 7, 2015, 1:28:17 p.m.
FVC_PRE Z-score-1.34 Z-score
FVC pre bronchodilation measured/predicted82 %
Forced vital capacity [Volume] Respiratory system by Spirometry --post bronchodilation4.7 LFVC normal bounds: >3.7 L
FVC_POST z-score-0.09 Z-score
FVC post bronchodilation measured/predicted99 %
FVC POST change (mL)600 mL
FVC percent change Respiratory system20 %

Moderately severe, partially reversible airflow obstruction.


Entry 9

Resource Observation:

Generated Narrative

code: Oxygen saturation in Arterial blood by Pulse oximetry --resting

value: 99 %


Entry 10

Resource Observation:

Test quality: A

Entry 11

Resource Observation:

Generated Narrative

code: FVC_PRE Z-score

value: -1.34 Z-score

derivedFrom:


Entry 12

Resource Observation:

Generated Narrative

code: FVC pre bronchodilation measured/predicted

value: 82 %

derivedFrom:


Entry 13

Resource Observation:

Generated Narrative

code: Forced vital capacity [Volume] Respiratory system by Spirometry --post bronchodilation

value: 4.7 L

ReferenceRanges

-LowType
*3.7 LFVC normal bounds

Entry 14

Resource Observation:

Generated Narrative

code: FVC_POST z-score

value: -0.09 Z-score

derivedFrom: Generated Summary: Forced vital capacity [Volume] Respiratory system by Spirometry --post bronchodilation; 4.7 L


Entry 15

Resource Observation:

Generated Narrative

code: FVC post bronchodilation measured/predicted

value: 99 %

derivedFrom: Generated Summary: Forced vital capacity [Volume] Respiratory system by Spirometry --post bronchodilation; 4.7 L


Entry 16

Resource Observation:

Generated Narrative

code: FVC POST change (mL)

value: 600 mL

derivedFrom:


Entry 17

Resource Observation:

Generated Narrative

code: FVC percent change Respiratory system

value: 20 %

derivedFrom: