Pulmonary Function Testing: An Interoperability on FHIR Implementation Guide
0.1.0
- ci-build
Pulmonary Function Testing: An Interoperability on FHIR Implementation Guide - Local Development build (v0.1.0). See the Directory of published versions
{
"resourceType" : "Composition",
"id" : "pft-composition",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>status</b>: preliminary</p><p><b>type</b>: <span title=\"Codes: {http://loinc.org 81458-2}\">Pulmonary function test panel</span></p><p><b>category</b>: <span title=\"Codes: {http://loinc.org 27896-0}\">Pulmonary studies (set)</span></p><p><b>encounter</b>: <a href=\"Bundle-pft-bundle.html#Encounter_encounter-01\">Generated Summary: type: collection</a></p><p><b>date</b>: 2017-02-20</p><p><b>author</b>: <a href=\"TODO_PLACEHOLDER\">TODO_PLACEHOLDER</a></p><p><b>title</b>: PFT: test panel Observations and DiagnosticReport</p><p><b>custodian</b>: <a href=\"Bundle-pft-bundle.html#Organization_organization-01\">Generated Summary: type: collection</a></p></div>"
},
"status" : "preliminary",
"type" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "81458-2",
"display" : "Pulmonary function test panel"
}
]
},
"category" : [
{
"coding" : [
{
"system" : "http://loinc.org",
"code" : "27896-0",
"display" : "Pulmonary studies (set)"
}
]
}
],
"subject" : {
"reference" : "Patient/patient-01"
},
"encounter" : {
"reference" : "Encounter/encounter-01"
},
"date" : "2017-02-20",
"author" : [
{
"reference" : "TODO_PLACEHOLDER"
}
],
"title" : "PFT: test panel Observations and DiagnosticReport",
"custodian" : {
"reference" : "Organization/organization-01"
},
"section" : [
{
"title" : "PFT Observations and Technician Comment",
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "30954-2",
"display" : "Relevant diagnostic tests/laboratory data Narrative"
}
]
},
"text" : {
"status" : "additional",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">TECHNICIAN COMMMENTS: No medications in past 24 hr. 400 mcg albuterol given for reversibility testing.</div>"
},
"entry" : [
{
"reference" : "SpO2_RESTING"
}
],
"section" : [
{
"title" : "Spirometry",
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "81459-0",
"display" : "Spirometry panel"
},
{
"system" : "http://loinc.org",
"code" : "81458-2",
"display" : "Pulmonary function test panel"
}
]
},
"text" : {
"status" : "additional",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">Reference values: GLI 2012 Test quality: Pre: FEV1 - A, FVC - A; Post: FEV1 - A, FVC - B</div>"
},
"entry" : [
{
"reference" : "Observation/FVC-PRE"
},
{
"reference" : "Observation/FVC-PRE-Zscore"
},
{
"reference" : "Observation/FVC-PRE-percentPredicted"
},
{
"reference" : "Observation/FVC-POST"
},
{
"reference" : "Observation/FVC-POST-Zscore"
},
{
"reference" : "Observation/FVC-POST-percentPredicted"
},
{
"reference" : "Observation/FVC-POST-mLChange"
},
{
"reference" : "Observation/FVC-post-percentChange"
}
]
},
{
"title" : "Slow Vital Capacity (Pre-Bronchodilator)",
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "81458-2",
"display" : "Pulmonary function test panel"
}
]
},
"text" : {
"status" : "additional",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">Reference values: VC - Gutierrez 2004; FEV1/VC - GLI 2012</div>"
}
},
{
"title" : "Multi-Breath Nitrogen Washout (Post-Bronchodilator)",
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "81458-2",
"display" : "Pulmonary function test panel"
}
]
},
"text" : {
"status" : "additional",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">Reference values: Gutierrez 2004; Test quality: QA met</div>"
}
},
{
"title" : "Plethysmography (Post-Bronchodilator)",
"code" : {
"coding" : [
{
"system" : "http://snomed.info/id",
"code" : "20552003",
"display" : "Plethysmography (procedure)"
}
]
},
"text" : {
"status" : "additional",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">Reference values: Gutierrez 2004; Test quality: QA met</div>"
}
},
{
"title" : "Diffusing Capacity (Post-Bronchodilator)",
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "81458-2",
"display" : "Pulmonary function test panel"
}
]
},
"text" : {
"status" : "additional",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">Reference values: GLI 2017; Test quality: one grade A test; P_B: 721 mmHg</div>"
}
}
]
},
{
"title" : "Pulmonologist interpretation of PFT and diagnosis",
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "59769-0",
"display" : "Postprocedure diagnosis Narrative"
}
]
},
"entry" : [
{
"reference" : "DiagnosticReport/diagnostic-report"
}
]
}
]
}