Pulmonary Function Testing: An Interoperability on FHIR Implementation Guide
0.1.0 - ci-build

Pulmonary Function Testing: An Interoperability on FHIR Implementation Guide - Local Development build (v0.1.0). See the Directory of published versions

: PFT Composition - JSON Representation

Raw json | Download


{
  "resourceType" : "Composition",
  "id" : "pft-composition",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>status</b>: preliminary</p><p><b>type</b>: <span title=\"Codes: {http://loinc.org 81458-2}\">Pulmonary function test panel</span></p><p><b>category</b>: <span title=\"Codes: {http://loinc.org 27896-0}\">Pulmonary studies (set)</span></p><p><b>encounter</b>: <a href=\"Bundle-pft-bundle.html#Encounter_encounter-01\">Generated Summary: type: collection</a></p><p><b>date</b>: 2017-02-20</p><p><b>author</b>: <a href=\"TODO_PLACEHOLDER\">TODO_PLACEHOLDER</a></p><p><b>title</b>: PFT: test panel Observations and DiagnosticReport</p><p><b>custodian</b>: <a href=\"Bundle-pft-bundle.html#Organization_organization-01\">Generated Summary: type: collection</a></p></div>"
  },
  "status" : "preliminary",
  "type" : {
    "coding" : [
      {
        "system" : "http://loinc.org",
        "code" : "81458-2",
        "display" : "Pulmonary function test panel"
      }
    ]
  },
  "category" : [
    {
      "coding" : [
        {
          "system" : "http://loinc.org",
          "code" : "27896-0",
          "display" : "Pulmonary studies (set)"
        }
      ]
    }
  ],
  "subject" : {
    "reference" : "Patient/patient-01"
  },
  "encounter" : {
    "reference" : "Encounter/encounter-01"
  },
  "date" : "2017-02-20",
  "author" : [
    {
      "reference" : "TODO_PLACEHOLDER"
    }
  ],
  "title" : "PFT: test panel Observations and DiagnosticReport",
  "custodian" : {
    "reference" : "Organization/organization-01"
  },
  "section" : [
    {
      "title" : "PFT Observations and Technician Comment",
      "code" : {
        "coding" : [
          {
            "system" : "http://loinc.org",
            "code" : "30954-2",
            "display" : "Relevant diagnostic tests/laboratory data Narrative"
          }
        ]
      },
      "text" : {
        "status" : "additional",
        "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">TECHNICIAN COMMMENTS: No medications in past 24 hr. 400 mcg albuterol given for reversibility testing.</div>"
      },
      "entry" : [
        {
          "reference" : "SpO2_RESTING"
        }
      ],
      "section" : [
        {
          "title" : "Spirometry",
          "code" : {
            "coding" : [
              {
                "system" : "http://loinc.org",
                "code" : "81459-0",
                "display" : "Spirometry panel"
              },
              {
                "system" : "http://loinc.org",
                "code" : "81458-2",
                "display" : "Pulmonary function test panel"
              }
            ]
          },
          "text" : {
            "status" : "additional",
            "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">Reference values: GLI 2012 Test quality: Pre: FEV1 - A, FVC - A; Post: FEV1 - A, FVC - B</div>"
          },
          "entry" : [
            {
              "reference" : "Observation/FVC-PRE"
            },
            {
              "reference" : "Observation/FVC-PRE-Zscore"
            },
            {
              "reference" : "Observation/FVC-PRE-percentPredicted"
            },
            {
              "reference" : "Observation/FVC-POST"
            },
            {
              "reference" : "Observation/FVC-POST-Zscore"
            },
            {
              "reference" : "Observation/FVC-POST-percentPredicted"
            },
            {
              "reference" : "Observation/FVC-POST-mLChange"
            },
            {
              "reference" : "Observation/FVC-post-percentChange"
            }
          ]
        },
        {
          "title" : "Slow Vital Capacity (Pre-Bronchodilator)",
          "code" : {
            "coding" : [
              {
                "system" : "http://loinc.org",
                "code" : "81458-2",
                "display" : "Pulmonary function test panel"
              }
            ]
          },
          "text" : {
            "status" : "additional",
            "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">Reference values: VC - Gutierrez 2004; FEV1/VC - GLI 2012</div>"
          }
        },
        {
          "title" : "Multi-Breath Nitrogen Washout (Post-Bronchodilator)",
          "code" : {
            "coding" : [
              {
                "system" : "http://loinc.org",
                "code" : "81458-2",
                "display" : "Pulmonary function test panel"
              }
            ]
          },
          "text" : {
            "status" : "additional",
            "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">Reference values: Gutierrez 2004; Test quality: QA met</div>"
          }
        },
        {
          "title" : "Plethysmography (Post-Bronchodilator)",
          "code" : {
            "coding" : [
              {
                "system" : "http://snomed.info/id",
                "code" : "20552003",
                "display" : "Plethysmography (procedure)"
              }
            ]
          },
          "text" : {
            "status" : "additional",
            "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">Reference values: Gutierrez 2004; Test quality: QA met</div>"
          }
        },
        {
          "title" : "Diffusing Capacity (Post-Bronchodilator)",
          "code" : {
            "coding" : [
              {
                "system" : "http://loinc.org",
                "code" : "81458-2",
                "display" : "Pulmonary function test panel"
              }
            ]
          },
          "text" : {
            "status" : "additional",
            "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">Reference values: GLI 2017; Test quality: one grade A test; P_B: 721 mmHg</div>"
          }
        }
      ]
    },
    {
      "title" : "Pulmonologist interpretation of PFT and diagnosis",
      "code" : {
        "coding" : [
          {
            "system" : "http://loinc.org",
            "code" : "59769-0",
            "display" : "Postprocedure diagnosis Narrative"
          }
        ]
      },
      "entry" : [
        {
          "reference" : "DiagnosticReport/diagnostic-report"
        }
      ]
    }
  ]
}